{"id":4633,"date":"2025-09-10T10:11:28","date_gmt":"2025-09-10T08:11:28","guid":{"rendered":"https:\/\/www.fluidz.nl\/?p=4633"},"modified":"2025-09-10T11:01:27","modified_gmt":"2025-09-10T09:01:27","slug":"get-the-most-out-of-your-cip-with-tank-cleaning","status":"publish","type":"post","link":"https:\/\/www.fluidz.nl\/en\/get-the-most-out-of-your-cip-with-tank-cleaning\/","title":{"rendered":"Optimal CIP Cleaning 4: Tank cleaning"},"content":{"rendered":"<h3>How to get the most out of your CIP system?<\/h3>\n<p>Part 4 of the hacks for optimal CIP cleaning: tank cleaning!<\/p>\n<p>In recent weeks, we&#8217;ve already discussed three key ingredients:<\/p>\n<ol>\n<li>Hygienic design<\/li>\n<li>Material selection<\/li>\n<li>Component selection<\/li>\n<\/ol>\n<p>This week, we&#8217;ll focus on ingredient 4: tank cleaning.<\/p>\n<p>Good design is the foundation. This prevents compromises or additional measures during cleaning.<\/p>\n<p><strong>Important for tank design:<\/strong><br \/>\n\u2714 Preferably choose a vertical tank<br \/>\n\u2714 Do not combine tank and line cleaning<br \/>\n\u2714 Ensure good pressure regulation on the CIP supply<br \/>\n\u2714 Direct and complete spraying has the greatest impact<br \/>\n\u2714 Adjust the spray pattern to the application (180\u00b0, 270\u00b0, 360\u00b0)<br \/>\n\u2714 Take obstacles into account, such as nozzles, baffles, filters, and ventilation\/venting<br \/>\n\u2714 Prevent loosened product from flowing back into the spray ball<br \/>\n\u2714 Avoid tank damage by correctly calculating ventilation\/venting<\/p>\n<p><strong>You can also optimize tank cleaning during use:<\/strong><br \/>\n\u2714 Regularly check the operation and condition of the spray balls<br \/>\n\u2714 Validate the spraying with the Riboflavin test<\/p>\n<p><strong>What is a Riboflavin test (fluorescence test)?<\/strong><br \/>\nThe surface is sprayed with a fluorescent riboflavin solution. After a CIP cycle, UV light is used to check whether everything has been properly cleaned.<\/p>\n<p>Could you use some help with your cleaning process?<br \/>\nFeel free to contact us.<br \/>\nWe&#8217;re ready to help!<\/p>\n<div id=\"attachment_4619\" style=\"width: 957px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4619\" class=\"size-full wp-image-4619\" src=\"https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Differences-in-spray-balls.jpg\" alt=\"\" width=\"947\" height=\"692\" srcset=\"https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Differences-in-spray-balls.jpg 947w, https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Differences-in-spray-balls-300x219.jpg 300w, https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Differences-in-spray-balls-768x561.jpg 768w\" sizes=\"auto, (max-width: 947px) 100vw, 947px\" \/><p id=\"caption-attachment-4619\" class=\"wp-caption-text\"><em>Comparison of different spray balls for tank cleaning<\/em><\/p><\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4621 size-full\" src=\"https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Mounting-method-spray-balls.jpg\" alt=\"What is the best mounting method for the spray ball for CIP cleaning?\" width=\"1024\" height=\"768\" srcset=\"https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Mounting-method-spray-balls.jpg 1024w, https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Mounting-method-spray-balls-300x225.jpg 300w, https:\/\/www.fluidz.nl\/wp-content\/uploads\/2025\/09\/Mounting-method-spray-balls-768x576.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><br \/>\n<em>Comparison of different installation methods for spray balls for tank cleaning<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>How to get the most out of your CIP system? Part 4 of the hacks for optimal CIP cleaning: tank cleaning! In recent weeks, we&#8217;ve already discussed three key ingredients: Hygienic design Material selection Component selection This week, we&#8217;ll focus on ingredient 4: tank cleaning. Good design is the foundation. This prevents compromises or additional [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":4620,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[379,332,804,361,615,803],"class_list":["post-4633","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-alfa-laval-en","tag-cip-en","tag-cipcleaning-en","tag-cleaning-in-place-en","tag-food-industry","tag-foodindustry-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/posts\/4633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/comments?post=4633"}],"version-history":[{"count":4,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/posts\/4633\/revisions"}],"predecessor-version":[{"id":4637,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/posts\/4633\/revisions\/4637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/media\/4620"}],"wp:attachment":[{"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/media?parent=4633"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/categories?post=4633"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fluidz.nl\/en\/wp-json\/wp\/v2\/tags?post=4633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}